Page - 62/72 ADEZP0DC - AC-2 FLASH INVERTER - User Manual
8) Press ENTER to clear these values.
Display will show 0.0.
' % '
' ' '
9) Select Forward Direction, close any interlock
switches that may be in the system.
MIN VACC MAX
0.0 - 0.0
10) Slowly depress the accelerator pedal (or tiller
butterfly) to its maximum value. The new minimum
and maximum voltages will be displayed on the
Console plus an arrow indicating the direction.
11) Select the Reverse Direction and repeat Item
10.
MIN VACC MAX
0.6 4.4
12) When finished, press OUT.
' ' '
' % '
13) The Display will ask: “ARE YOU SURE?”.
ARE YOU SURE
YES=ENTER NO=OUT
14) Press ENTER for yes, or OUT for NO.
' % '
' % '
15) When finished, the Console shows:
MAIN MENU
PROGRAM VACC
16) Press OUT again to return to the Opening Zapi
Menu.
' ' '
' % '
Page view 61