Page - 38/72 ADEZP0DC - AC-2 FLASH INVERTER - User Manual
8) ADJUSTMENT #04
This parameter determines the motor temperature level at which the “Motor
temperature” alarm is signalled. The range is from 70 °C to 160 °C with 10 °C
steps. This parameter must be adjusted only if the “Set temperature” (menu
“Set option”) parameter is programmed “Analog”.
9) ADJUSTMENT #03
This parameter isn't used.
10) ADJUSTMENT #02
It adjust the lower level of the battery discharge table.
11) ADJUSTMENT #01
It adjusts the upper level of the battery discharge table.
12) LOAD HM FROM MDI
For an explanation of this point see the MDI instrument handbook.
13) CHECK UP DONE
For an explanation of this point see the MDI instrument handbook.
14) CHECK UP TYPE
For an explanation of this point see the MDI instrument handbook.
15) PWM ON MAIN CONT
- OFF: the inverter applies the battery voltage to the loads on the main
contactor coil.
- ON: the PWM reduces the voltage at the loads on the main contactor
coil down to 62% of the battery voltage.
16) PWM ON AUX OUT.
- OFF: the inverter applies the battery voltage to the loads on the auxiliary
output.
- ON: the PWM reduces the voltage at the loads on the auxiliary output
down to 62% of the battery voltage.