6.2 Connectors of the logic - Pump configuration
A1 PCLRXD Positive serial reception.
A2 NCLRXD Negative serial reception.
A3 PCLTXD Positive serial transmission.
A4 NCLTXD Negative serial transmission.
A5 GND Negative console power supply.
A6 +12 Positive console power supply.
A7 FLASH It must be connected to A8 for the Flash memory
programming.
A8 FLASH It must be connected to A7 for the Flash memory
programming.
B1 -BATT -Batt.
B2 MODE This input allows the customer to select the software
for traction or lifting application.