ADEZP0DC - AC-2 FLASH INVERTER - User Manual Page - 17/72
detects a failure in the "SAFETY" circuit, the microcontroller itself will bring the
machine in a safe status.
Suggested connection of "SAFETY" circuit:
- STANDALONE CONFIGURATION:
it is suggested to connect safety input to
the "SEAT" microswitch or to the "DEADMAN" microswitch (it depends on the
application); in this way the machine will be brought to a safe status as soon as
the operator leaves the machine.
- COMBI CONFIGURATION:
in this case the pump controller acts as
supervisor, checking the traction controller functionality by the CANBUS. So it is
suggested to connect the "SAFETY" input of traction controller to a dedicated
output of pump controller, so that the pump controller can drive the traction safety
input and open the power line in case of malfunctioning of traction controller.
4.4 EMC
U EMC and ESD performances of an electronic system are strongly
influenced by the installation. Special attention must be given to the
lengths and the paths of the electric connections and the shields. This
situation is beyond ZAPI's control. Zapi can offer assistance and
suggestions, based on its years experience, on EMC related items.
However, ZAPI declines any responsibility for non-compliance,
malfunctions and failures, if correct testing is not made. The machine
manufacturer holds the responsibility to carry out machine validation,
based on existing norms (EN12895 for industrial truck; EN50081-2 for other
applications).
EMC stands for Electromagnetic Compatibility, and it represents the studies and
the tests on the electromagnetic energy generated or received by an electrical
device.
So the analysis works in two directions:
1) The study of the emission problems, the disturbances generated by the
device and the possible countermeasure to prevent the propagation of that
energy; we talk about “conduction” issues when guiding structures such as
wires and cables are involved, “radiated emissions” issues when it is studied
the propagation of electromagnetic energy through the open space. In our
case the origin of the disturbances can be found inside the controller with the
switching of the mosfets which are working at high frequency and generate
RF energy, but wires and cables have the key role to propagate the
disturbs because they works as antennas, so a good layout of the cables
and their shielding can solve the majority of the emission problems.
2) The study of the immunity can be divided in two main branches: protection
from electromagnetic fields and from electrostatic discharge.
The electromagnetic immunity concern the susceptibility of the controller
with regard to electromagnetic fields and their influence on the correct work
made by the electronic device.
There are well defined tests which the machine has to be exposed to.
These tests are carried out at determined levels of electromagnetic fields, to
simulate external undesired disturbances and verify the electronic devices
response.