8) RELEASE BRAKING
Seconds. It controls the deceleration ramp when the pump request is
released. The parameter sets the time needed to decelerate the traction
motor from 100Hz to 0Hz.
9) MAX SPEED LIFT
It determines the pump maximum speed when LIFT ENABLE switch is
closed .
10) 1ST SPEED COARSE
It determines the pump maximum speed when SPEED1 switch is closed .
11) 2ND SPEED COARSE
It determines the pump maximum speed when SPEED2 switch is closed .
12) 3RD SPEED COARSE
It determines the pump maximum speed when SPEED3 switch is closed.
13) HYD SPEED FINE
It determines the pump maximum speed when an hydraulic steering function
request is received via CAN BUS.
14) CUTBACK SPEED 1
Speed reduction when the cutback input is active.
15) FREQUENCY CREEP
Minimum speed when the LIFT ENABLE switch is closed, but the accelerator
is on a minimum position.
16) MAXIMUM CURRENT
This parameter changes the maximum current of the inverter.
17) AUXILIARY TIME
Time units value (seconds). For the encoder version, is the delay when an
hydraulic steering function request is switched off.