Page - 40/83 AF2ZP0CE - ACE2 350/450 - User Manual
7) BATT. MAX. ADJ.
It adjusts the upper level of the battery discharge table. It is used to calibrate
the discharge algorithm with the battery of the application. See chapter 9.5
for more information.
8) ADJUSTMENT #03
This parameter adjusts the updating of battery charge after Key-On.
Decreasing this parameter the minimum difference between the battery
voltage measured after Key-On and the last stored value, necessary to
update the charge with the new value measured, decrease. It is used to
calibrate the discharge algorithm with the battery of the application. See
chapter 9.5 for more information.
9) LOAD HM FROM MDI
When set On, the HourMeter of the Controller is transferred and recorded on
the HourMeter of the Standard MDI (connected on the Serial Link).
10) CHECK UP DONE
Turn it On when the required Maintenance service has been executed to
cancel the CHECK UP NEEDED warning.
11) CHECK UP TYPE
It specifies the handling of the CHECK UP NEEDED warning:
- NONE: No CHECK UP NEENED warning
- OPTION#1: CHECK UP NEENED warning shown on the hand set and
MDI after 300 hours
- OPTION#2: Equal to OPTION#1 but Speed reduction after 340 hours
- OPTION#3: Equal to OPTION#2 but the truck definitively stops after 380
hours
12) MAIN CONT VOLT
It specifies the percentage of battery voltage supplied to MC coil to close the
contactor.
13) AUX OUT VOLT
It specifies the percentage of battery voltage supplied to AUX coil to close the
AUXILIARY electro valve.
14) MAIN CONT. V RID
It specifies the percentage of MAIN CONT VOLT parameter, supplied to MC
coil to keep the contactor closed.
Example 1
MAIN CONT VOLTAGE = 100%
MAIN CONT V RID = 70%
The contactor will be closed with full battery voltage applied to the coil and
then the voltage will be reduced to 70% of battery voltage.
Example 2
MAIN CONT VOLTAGE = 70%
MAIN CONT V RID = 100%
The contactor will be closed with 70% of battery voltage applied to the coil
and then the voltage will be kept at the same value.
Example 3
MAIN CONT VOLTAGE = 70%
MAIN CONT V RID = 70%
The contactor will be closed with 70% of battery voltage applied to the coil