8.10 Description of the Console “SAVE” function
The SAVE function allows the operator to transmit the Parameter values and
Configuration data of the inverter into the Console memory. It is possible to load
64 different programmes.
The information saved in the Console memory can then be reloaded into another
inverter using the RESTORE function.
The data that is available via the SAVE function is as follows:
- All Parameter Values (PARAMETER CHANGE).
- Options (SET. OPTIONS).
- The Level of the Battery (ADJUST BATTERY).
Flow Chart showing how to use the SAVE function of the Digital Console.
1) Opening Zapi Display.
AE2T2B ZP0.12
24V 400A 00000
2) Press ENTER to go into the General menu.
' % '
' ' '
3) The Display will show:
MAIN MENU
PARAMETER CHANGE
4) Press ROLL UP or ROLL DOWN button until
SAVE PARAM. appears on the display.
% ' '
% ' '
5) The Display will show:
MAIN MENU
SAVE PARAM.
6) Press ENTER to go into the SAVE function.
' % '
' ' '
7) If this facility has been used before the type of
inverter data stored appears on the top Main with a
2 digit reference.
SELECT: MOD. 00
FREE
8) Keep pressing either ROLL UP or ROLL DOWN
keys until the second Main indicates a FREE
storage facility.
% ' '
% ' '
SELECT: MOD. 01
FREE
9) Press ENTER to commence SAVE routine.
' % '
' ' '
10) You can see the items that are being stored
whilst the SAVE routine is happening.
READING …
ACCEL. DELAY (ECC.)
11) When finished, the Console shows:
MAIN MENU
SAVE PARAM
12) Press OUT to return to the Opening Zapi
Display.
' ' '
' % '